Volkswagen Polo Service & Repair Manual: Battery Charger -VAS5095A- Maintenance Charging
WARNING
Risk of injury. Follow all Warnings and Safety
Precautions. Refer to
→ Chapter „Warnings and Safety Precautions“. |
|
WARNING
Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
not be used! |
There is a risk of explosion during testing,
charging or jump starting. |
These batteries must be replaced. |
|
During maintenance charging, the Battery Charger -VAS5095A-
provides safe charging and preserves the charge of the battery. |
– |
Proceed as when charging the battery. Refer to
→ Chapter „Battery, Charging with Battery Charger -VAS5095A-“. |
Note
If the battery is discharged by an electrical consumer
during maintenance charging, the Battery Charger -VAS5095A-
automatically supplies the appropriate charge. |
Maintenance charging can be performed without time
restrictions. |
The battery can be used constantly. |
|
General Information
The support mode provides the vehicle electrical system with
voltage when the battery is removed or disconnected.
...
Other materials:
Electrically Driven A/C Compressor, Flushing
Vehicles with a high voltage system
Observe all of the additional warnings for all work
performed on vehicles with the high voltage system. Refer to
→ Electrical Equipment; Rep. Gr.93.
...
Charging Systems not Requiring a Permit
At this time, A/C service units for extracting, cleaning and
filling refrigerant for motor vehicle A/C systems are available
from various manufacturers.
Charging systems not requiring a permit are ones used for
transferring compressed ga ...
Coolant Fan Control Module -J293
Note
Available in different construction styles, some installed
on coolant fan -arrows-.
This control module switches on and off the A/C clutch and
therefore the A/C compressor. It switche ...