VW Polo manuals

Volkswagen Polo Service & Repair Manual: Battery Charger -VAS5900- Maintenance Charging

  Note
If the battery is discharged by an electrical consumer during maintenance charging, the Battery Charger -VAS5900- automatically supplies the appropriate charge.
Maintenance charging can be performed without time restrictions.
The battery can be used constantly.
Observe the maintenance notes of the battery manufacturer.
  WARNING
Risk of injury. Follow all Warnings and Safety Precautions. Refer to → Chapter „Warnings and Safety Precautions“.
  WARNING
Batteries that have a light yellow visual indicator do not have to be tested or charged. Jump starting must not be used!
There is a risk of explosion during testing, charging or jump starting.
These batteries must be replaced.
If the battery is fully charged, the Battery Charger -VAS5900- starts maintenance charging.
–  Proceed as when charging the battery. Refer to → Chapter „Battery, Charging with Battery Charger -VAS5900-“.
   
With a charge status of 100%, all bars are indicated on the display.
 

Battery Charger -VAS5900- Maintenance Charging

Support Mode with Battery Charger -VAS5900
General Information The support mode provides the vehicle electrical system with voltage when the battery is removed or disconnected. ...

Battery Charger -VAS5903
...

Other materials:

Explanation of Test Results
1 -  Type of test. 2 -  Battery test result. 3 -  Measured voltage 4 -  Measured cold start value. 5 -  Cold st ...

Charging Systems not Requiring a Permit
At this time, A/C service units for extracting, cleaning and filling refrigerant for motor vehicle A/C systems are available from various manufacturers. Charging systems not requiring a permit are ones used for transferring compressed ga ...

Improvised Tools
  Note This list outlines the testers, tools and materials required for expert refrigerant circuit repair work.   Caution Non-approved tools or materials such as leak sealing additiv ...