At this time, A/C service units for extracting, cleaning and filling refrigerant for motor vehicle A/C systems are available from various manufacturers.
Group 3:
Mobile extraction and charging systems for filling compressed-gas vessels permanently connected to the system.
The refrigerant or refrigerant/oil mixture is transferred to compressed gas vessels which are permanently connected to the mobile systems. In accordance with 3 Para. 5 No. 3 of pressure vessel regulations, compressed-gas vessels are classified as pressure vessels in this case.
The charging systems require:
no permit
no expert testing as the gas is transferred to compressed-gas vessels which are classed as being pressure vessels. (Systems used for transfer from these pressure vessels to compressed-gas vessels for supplying to third parties do require a permit and are subject to mandatory testing).
  Note
The A/C service and recycling units used in motor vehicle workshops are extraction and charging systems not requiring a permit (Group “3”) but which are only to be operated by qualified personnel. Instructions for unit operation and maintenance can be found in the relevant manufacturer's documentation.
   
A/C Service and Recycling Units
...

Charging Systems not Requiring a Permit
At this time, A/C service units for extracting, cleaning and filling refrigerant for motor vehicle A/C systems are available from various manufacturers. ...

Other materials:

Waxing and polishing the vehicle
First read and observe the introductory information and safety warningsWaxing Waxing protects the paintwork. You will need to re-wax the vehicle with a good hard wax if water no longer clearly forms small drops and runs off the paintwork when it is clean. Even if a wax solution is used regul ...

Refrigerant Circuit, Tracing Leaks, with Leak Detection System -VAS6196- or Leak Detection Kit -VAS6201A- or Succeeding Model
  Note This repair manual describes different methods for detecting leaks in the refrigerant circuit. These methods have been tested and result in success when used correctly. If when searching for compressed air / Nit ...

Crimping Pliers - .35-2.5mm -VAS1978/1A
The Crimping Pliers - .35-2.5mm -VAS1978/1A- or the Wiring Harness Repair - Crimping Plier - Base Tool -VAS1978/1-2- together with the Wiring Harness Repair - Crimping Head - .35-2.5mm -VAS1978/1-1-, or the Wiring Harness Repair Set - Crimping Head - 4-6 ...

© 2016-2026 Copyright www.vwpolo.net