Volkswagen Polo Service & Repair Manual: Warranty Test, Performing
WARNING
| Do not check or charge batteries that have a visual
indicator that is bright yellow. Jump starting must not
be used! |
| There is a risk of explosion during testing,
charging or jump starting. |
| These batteries must be replaced. |
|
| – |
Select “Warranty Test”. |
| – |
Select “inside the vehicle” or “outside of the vehicle”. |
| – |
Select “at the battery pole” or “at the battery jump start
terminal”. |
| – |
Scan in the battery 2D code or manually select battery type
and current strength. |
| – |
Measure the temperature. Hold the temperature sensor
approximately 5 cm above the battery pole until the temperature
is stable. |
| – |
Print out the test report if necessary. |
|
Special tools and workshop equipment
required
Battery Tester -VAS6161-
WARNING
...
WARNING
Do not check or charge batteries that have a visual
indicator that is bright yellow. Jump starting must not
...
Other materials:
Refrigerant Circuit with A/C Service Station, Filling
Caution
If it is suspected that chemicals were added to the
refrigerant circuit to seal leaks, do not connect the
A/C service station and do not extract the refrigerant.
...
Preserving Wax (Spray Can)
Definition:
Preserving Wax -D 308 SP5 A1-
Edition 04/2009
Product Description
The Preserving Wax -D 308 SP5 A1- provides optimal corrosion
protection for areas in the body th ...
Battery, Charging
Requirements
WARNING
Batteries that have a light yellow visual indicator
do not have to be tested or charged. Jump starting must
not be used!
There is a risk ...